Applicable U Sheet Pile

Applicable Sheet Piles

U Press-in Piling

 

Typical Cross Section

   
 

U Pile Sections listed below are technically applicable to the current U Piler models. For detailed pile dimensions and properties, please contact your pile supplier. Pile name, dimensions, properties, production and availability are subject to alteration by pile manufacturers without prior notice. Selecting the most suitable section to your specific projects, please consult experienced Giken engineers in your nearest Giken office.

 

Major Properties

Updated: 22 Feb. 2002

Pile Width 500 ~ 525 mm

Section
Width
(Nominal)

Height
of Wall
(Nominal)

Thickness

Per 1 m of Wall

Web

Flange

Moment
of Inertia

Section
Modulus

Mass

Section Modulus

Section Designation

Manufacturer

Section

mm

mm

mm

mm

cm4/m

cm3/m

kg/m2

1,600

Arbed

L2S

500

340

12.3

9.0

27,200

1,600

139.0

2,000

Arbed

L3S

500

380

14.1

10.0

40,010

2,000

158.0

Hoesch

23

500

420

11.5

10.0

42,000

2,000

155.0

Corus

20Wd

525

400

11.3

10.0

40,574

2,028

153.7

2,500

Hoesch

24

500

420

15.6

10.0

52,500

2,500

175.0

Arbed

L4S

500

440

15.5

10.0

55,010

2,500

176.0

Hoesch

24/12

500

420

15.6

12.0

53,610

2,550

185.0

3,000

Hoesch

25

500

420

20.0

11.5

63,840

3,040

206.0

3,100

Japanese

500

400

24.3

 

63,000

3,150

210.0

3,800

Japanese

500

450

27.6

 

86,000

3,820

240.0

4,200

Corus

L6-42

500

450

20.5

14.0

94,680

4,208

265.4