Applicable Tubular Sheet Pile

Applicable Sheet Piles

Tubular Press-in Piling

 

Typical Cross Section (D900mm)

 

Details of P-T Interlock

 

 

Major Properties

Up: 22 Feb. 2002

Steel Tubular Pile (Main Body) per Pile

P-T Interlock Tubular Sheet Pile per1 m of wall

Outer
Diameter

Thick-
ness

Sectional
Area

Moment
of Inertia

Section
Modulus

Mass

Nominal
Pitch

Sectional
Area

Moment
of Inertia

Section
Modulus

Mass

mm

mm

cm2

cm4

cm3

kg/m

mm

cm2/m

cm4/m

cm3/m

kg/m2

1,300

14

444.0

117 x 104

180 x 102

444

1,480

421.4

790 x 103

122 x 102

331

15

475.0

125 x 104

192 x 102

475

448.4

845 x 103

130 x 102

352

16

507.0

133 x 104

205 x 102

507

475.3

899 x 103

138 x 102

373

17

538.0

141 x 104

217 x 102

538

502.2

953 x 103

147 x 102

394

18

569.0

149 x 104

229 x 102

569

529.1

101 x 104

155 x 102

415

19

600.0

157 x 104

241 x 102

600

555.9

106 x 104

163 x 102

436

1,400

15

652.7

157 x 104

224 x 102

512

1,580

449.9

991 x 103

142 x 102

353

16

695.7

167 x 104

238 x 102

546

477.0

105 x 104

151 x 102

375

17

738.6

177 x 104

252 x 102

580

504.2

112 x 104

160 x 102

396

18

781.5

187 x 104

267 x 102

613

531.4

118 x 104

169 x 102

417

19

824.3

196 x 104

281 x 102

647

558.5

124 x 104

178 x 102

438

1,500

15

699.8

193 x 104

257 x 102

549

1,680

451.1

115 x 104

153 x 102

354

16

745.9

205 x 104

274 x 102

586

478.6

122 x 104

163 x 102

376

17

792.0

218 x 104

290 x 102

622

506.0

130 x 104

173 x 102

397

18

838.0

230 x 104

307 x 102

658

533.4

137 x 104

183 x 102

419

19

884.0

242 x 104

323 x 102

694

560.8

144 x 104

192 x 102

440

 

Tubular sheet piles above are technically applicable to the current Tubular Piler models. Selecting the most suitable section to your specific projects, please consult experienced Giken engineers in your nearest Giken office.