Applicable Tubular Sheet Pile

Applicable Sheet Piles

Tubular Press-in Piling

 

Typical Cross Section (D900mm)

 

Details of P-T Interlock

 

 

Major Properties

Up: 22 Feb. 2002

Steel Tubular Pile (Main Body) per Pile

P-T Interlock Tubular Sheet Pile per1 m of wall

Outer
Diameter

Thick-
ness

Sectional
Area

Moment
of Inertia

Section
Modulus

Mass

Nominal
Pitch

Sectional
Area

Moment
of Inertia

Section
Modulus

Mass

mm

mm

cm2

cm4

cm3

kg/m

mm

cm2/m

cm4/m

cm3/m

kg/m2

500

9

138.8

418 x 102

187 x 10

109

680

289.6

615 x 102

246 x 10

227

10

153.9

462 x 102

185 x 10

121

311.8

680 x 102

272 x 10

245

11

169.0

505 x 102

202 x 10

133

334.0

743 x 102

297 x 10

262

12

184.0

548 x 102

219 x 10

144

356.0

806 x 102

322 x 10

280

13

198.9

590 x 102

236 x 10

156

377.9

868 x 102

347 x 10

297

14

213.8

632 x 102

253 x 10

168

399.8

929 x 102

372 x 10

314

600

9

167.1

730 x 102

243 x 10

131

780

288.7

936 x 102

312 x 10

227

10

185.4

807 x 102

269 x 10

145

312.1

103 x 103

345 x 10

245

11

203.5

883 x 102

294 x 10

160

335.4

113 x 103

377 x 10

263

12

221.7

958 x 102

319 x 10

174

358.7

123 x 103

410 x 10

282

13

239.7

103 x 103

344 x 10

188

381.8

132 x 103

441 x 10

300

14

257.7

111 x 103

369 x 10

202

404.9

142 x 103

473 x 10

318

15

275.7

118 x 103

393 x 10

216

427.9

151 x 103

504 x 10

336

16

293.6

125 x 103

417 x 10

230

450.8

161 x 103

535 x 10

354

 

Tubular sheet piles above are technically applicable to the current Tubular Piler models. Selecting the most suitable section to your specific projects, please consult experienced Giken engineers in your nearest Giken office.